ACOP.NET API
AcopOval
AcopLine1.jpg

Acop Oval Example

Use the ACOP Oval for displaying an ellipse in a synoptic display.

Most of the closed shape synoptics allow an additional spot (with heat map) to be displayed on the shape. See the 'Spot' Property below for details.

AcopOvalDisplayProperties.jpg

Acop Oval display Properties

Blink set the mode for the oval shape

  • off (default)
  • onWarning
  • always

BlinkIntensity set the blink intensity for the table cells (up to 100% lighter or -100% darker) (default = 50)
BlinkInterval set the blink interval (msec) for the table cells (default = 500)
BlinkSlot set the blink slot for the table cells (0 up to NumberBlinkSlots) (default = 0)
BorderColor border color of region
BorderWidth border width of region
DisplayText if true: display input text/readback value on shape
DisplayValue if non-empty then the displayed value upon update will be the value given
FillColor background color of region
Gradient color gradient for filled region
GradientStyle color gradient style for filled region
HiWarnFillColor color of display region when the readback value exceeds the high threshold
HiWarnTextColor color of display text when the readback value exceeds the high threshold
LowWarnFillColor color of display region when the readback value exceeds (negative direction) the low threshold
LowWarnTextColor color of display text when the readback value exceeds (negative direction) the low threshold
NumberBlinkSlots set the number of blink slots for the table cells (at least 2) (default = 2)
Precision precision to use for floating point numbers (0 = general display)
Spot parameters to acquire and display a spot on the synoptic display.
RotateText if true: apply rotation angle to displayed text
RotationAngle rotation angle of bounding rectangle region
TextColor color of display text in bounding rectangle region
TextFont font of display text in bounding rectangle region
ThresholdHighWarn if the link data is numerical, then the threshold provided is used for comparisons with the monitored data
ThresholdLowWarn if the link data is numerical, then the threshold provided is used for comparisons with the monitored data
ThresholdMatch if non-empty and the link data is non-numerical, then the string provided is used for comparisons with the monitored data
ToolTipText specifies the preferred tooltip text for table. If un-specified, then the address parameters will be used.
Units the value units (applied to the component's description)

AcopSpotDisplayProperties.jpg

Acop Spot display Properties

Active denotes whether the spot is actively accessing and displaying the given
HotColor is the color of the hot region of the spot
PositionServer is the server address containing the X and Y positions
RadiusMaximum is the maximum radius of the spot.
RadiusMinimum is the minimum radius of the spot.
SpotColor is the primary spot color
XMaximum is the maximum X position coordinates
XMinimum is the minimum X position coordinates
XPositionDevice is the device portion of the X position target address
XPositionProperty is the property of the X position target address
YMaximum is the maximum Y position coordinates
YMinimum is the minimum Y position coordinates
YPositionDeviceis the device portion of the Y position target address
YPositionProperty is the property of the Y position target address


Datenschutzerklaerung   -   Data Privacy Policy
Generated for ACOP.NET API by  doxygen 1.5.8